Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Odontol.sanmarquina (Impr.) ; 26(3): e23255, jul.-set.2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1538053

ABSTRACT

Uno de los mayores retos de la odontología actual es lograr una adhesión duradera y estable entre los materiales de restauración y los tejidos dentales. Los protocolos adhesivos han ido cambiando a lo largo del tiempo para cumplir con dicho objetivo, tratando de mantener la integridad de la capa hibrida, por lo que se revisaron los factores que provocan la degradación de la capa hibrida y los mecanismos propuestos para prevenir esta degradación. Se realizó una investigación y recopilación de información bibliográfica especializadas en el tema, en buscadores científicos como PubMed, Scielo, Redalyc, Medigraphic y Scopus. Para los criterios de inclusión se consideraron años de publicación entre el año 2002 al 2022, enfocados en trabajos de investigación relacionados con la degradación de la interfaz de unión resina-dentina y mecanismos para prevenir esta degradación en la capa híbrida. El mecanismo mas estudiado a corto y largo plazo es la aplicación de clorhexidina, la cual se utiliza después del ácido fosfórico y antes del adhesivo, inhibe la actividad proteolítica de las metaloproteinasas de la matriz (MMPs) y retarda la degradación de las fibras colágenas, consiguiendo de esta manera una mayor vida de las restauraciones adhesivas.


One of the biggest challenges in dentistry is to achieve a long-lasting and stable bond between restorative materials and dental tissues. The adhesive protocols have been changing over time to meet this objective, trying to maintain the integrity of the hybrid layer, so the factors that cause the degradation of the hybrid layer and the mechanisms proposed to prevent this degradation were reviewed. An investigation and compilation of specialized bibliographic information on the subject was carried out, in scientific search engines such as PubMed, Scielo, Redalyc, Medigraphic, Scopus, among others, as well as books. For the inclusion criteria, years of publication between 2002 and 2022 were considered, focused on research works related to the degradation of the resin-dentin bonding interface and mechanisms to prevent this degradation in the hybrid layer. The placement of CHX is used after the application of phosphoric acid and before the adhesive, it inhibits the proteolytic activity of matrix metalloproteinases (MMPs) and the degradation of collagen fibers, thus achieving a longer life of resin dental restorations.

2.
Rev. odontol. mex ; 22(1): 35-39, ene.-mar. 2018. graf
Article in Spanish | LILACS | ID: biblio-961588

ABSTRACT

Resumen Un material de retroobturación como el MTA (Mineral Trioxide Aggregate) debe de ser de fácil manejo, biocompatible, tener baja o nula solubilidad y ser dimensionalmente estable para evitar filtraciones asociadas a los cambios volumétricos. Objetivo: Medir la filtración en un cemento dental tipo MTA modificado con wollastonita y vidrio bioactivo. Material y métodos: Se establecieron ocho grupos: MTA Angelus (control), MTA Exp (cemento Portland blanco más 20 wt% de trióxido de bismuto), otros seis grupos se formaron con la adición de 10, 20 y 30 wt% de wollastonita y vidrio bioactivo al MTA Exp. Dientes permanentes uniradiculares, raíz recta y con ápice cerrado fueron preparados con técnica crown-down con fuerzas balanceadas para obtener un diámetro estandarizado a lima apical maestra #40. Se cortaron 3 mm del ápice se prepararon retrocavidades de 3 mm de profundidad con punta de ultrasonido donde fueron colocados los cementos, el extremo apical fue sumergido en solución de azul de metileno al 2% durante 24 horas. Resultados: MTA Exp fue el que presentó menor filtración con un promedio de 0.66 mm, mientras que el grupo de WO10 fue el de mayor con 1.61 mm. MTA Angelus usado como control presentó 0.71 mm de microfiltración, se encontraron diferencias estadísticamente significativas con WO10, (ANOVA p < 0.001, Dunett p < 0.001). Conclusiones: Se observa que en el caso de los cementos con los agregados de wollastonita y vidrio bioactivo la microfiltración disminuye conforme aumenta el porcentaje del agregado, se sugiere el uso de otras técnicas complementarias para medir la microfiltración.


Abstract Retro-filling material such as MTA (mineral trioxide aggregate) should be biocompatible, easy to handle, with low or nil solubility as well as dimensionally stable in order to avoid filtrations associated to volumetric changes. Objective: To measure filtration in a MTA-type dental cement modified with wollastonite and bioactive glass. Material and methods: Eight groups were established: MTA Angelus (control), MTA Exp (white Portland cement plus 20% wt of bismuth trioxide), another six groups were formed with the addition to MTA Exp of 10, 20 and 30% wt of wollastonite and bioactive glass . Single rooted teeth, with straight root and closed apex were prepared with crown-down technique with balanced forces in order to obtain standardized diameter to fit a number 40 master apical file; 3 mm from the apex were excised, 3 mm deep retro-cavities were prepared with ultrasound point, where cements were placed, apical end was submerged in a 2% methylene blue solution for 24 hours. Results: MTA Exp exhibited least filtration with an average of 0.66 mm, WO10 group exhibited the greatest leakage with average of 1.61 mm. MTA Angelus, used as control exhibited 0.71 mm microleakage. Statistically significant differences were found with WO10, (ANOVA p < 0.001), Dunett p < 0.001). Conclusions: It was observed that in the case of cements with aggregate of wollastonite and bioactive glass, microleakage decreased according to the aggregate's percentage. For microleakage measurement, use of other supporting techniques is advised.

3.
Rev. odontol. mex ; 20(3): 187-192, jul.-sep. 2016. tab, graf
Article in Spanish | LILACS | ID: biblio-961568

ABSTRACT

Resumen: El mineral trióxido agregado (MTA) es un cemento usado principalmente para sellar perforaciones en órganos dentales debido a que endurece en presencia de humedad, está compuesto por cemento Portland y trióxido de bismuto. Objetivo: Analizar y comparar por medio de PIXE, DSC, TGA y DRX la composición química elemental y de fases del cemento MTA Angelus® y de un cemento Portland blanco (CPB-CA). Material y métodos: MTA Angelus® blanco y un cemento Portland blanco fueron analizados con PIXE en un acelerador de partículas; el análisis de fases cristalinas se realizó por medio de DRX y contrastado los picos con los de base de datos del ICDD, el DSC se realizó en un calorímetro hasta 900 °C. Resultados: PIXE detectó como elementos de mayor porcentaje fueron aluminio, silicio y calcio para ambos cementos; habiendo diferencias en los porcentajes de azufre; el bismuto sólo se detectó en MTA Angelus®. Se detectaron como elementos traza cobre y estroncio en el MTA Angelus®, además de zirconio en CPB-CA. La relación entre silicio-calcio y silicio-aluminio en los dos cementos es similar. Se identificaron tres fases cristalinas en ambos cementos, silicato dicálcico, silicato tricálcico y aluminato tricálcico; sin embargo, se identificó Bismita en el MTA Angelus® y sulfato de calcio en forma de yeso en CPB-CA, que se logró corroborar con la ayuda de la técnica DSC. Conclusiones: Se logró observar la baja cantidad de yeso en MTA Angelus® por medio de la calorimetría. Tanto las fases cristalinas como la composición química elemental son similares en ambos cementos.


Abstract: Mineral trioxide aggregate (MTA) is a cement mainly used to seal tooth perforations; this is due to the fact that it hardens when in presence of humidity. It is composed of Portland cement and Bismuth trioxide. Objective: To analyze and compare with PIXE, DSC, TGA and DRX elementary chemical and phase composition of MTA Angelus® cement with a white Portland cement (WPC). Material and methods: MTA Angelus® white and a white Portland cement were analyzed with PIXE in a particle accelerator, phase analyses were conducted with XRD contrasting peaks with those in the ICDD database. DSC was conducted in a calorimeter up to 900 oC. Results: PIXE detected the following as greater percentage elements: aluminum, silica and calcium for both cements. Differences were found with sulfur percentages; Bismuth was only detected in MTA Angelus®. Trace elements of copper and strontium were detected in MTA Angelus® and zirconium in WPC. Relationship between silica-calcium and silica-aluminum was similar in both cements. In both cements, three crystalline phases were detected: dicalcium silicate, tricalcium silicate and tricalcium aluminate. Nevertheless, Bismite was identified in MTA Angelus® and calcium sulfate in the form of gypsum in WPC, this was corroborated with DSC technique. Conclusions: In MTA Angelus®, low gypsum amounts were observed by means of calorimetry. In both cements, crystalline phases and elemental chemical composition were similar.

SELECTION OF CITATIONS
SEARCH DETAIL